Performance of a Chromolith RP-18e column for the screening of β-blockers
2009
The chromatographic performance of a monolithic column (Chromolith RP-18e) was comprehensively examined in the isocratic separation of ten beta-blockers, using ACN-water mobile phases, and compared with the performance of three microparticulate RP columns manufactured with different types of silica: Spherisorb ODS-2, Kromasil C18 and XTerra MS C18. The comparison considered the analysis time, selectivity, peak shape (column efficiency and asymmetry) and resolution, and was extended to a wide range of mobile phase compositions. The Chromolith column showed good performance for the analysis of beta-blockers with regard to the packed columns. In terms of selectivity and analysis time, the grea…
Interpretive optimisation of organic solvent content and flow-rate in the separation of β-blockers with a Chromolith RP-18e column
2009
The chromatographic performance of a Chromolith RP-18e column was comprehensively examined for a group of basic drugs (beta-blockers), eluted with isocratic ACN-water mixtures at increasing flow-rate up to 6 mL/min. As the flow-rate increases at fixed mobile phase composition, peak distribution (selectivity) is maintained, but the relative peak widths increase. This reduces the resolution below satisfactory values for closely eluting compounds. With the monolithic column, flow-rate becomes thus an important factor to be optimised, in addition to the mobile phase composition. Since, theoretically, retention factors (k) are independent of the flow-rate, the classical quadratic model relating …
Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins
2007
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Bo…
Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to c…
2011
Abstract The performance of a monolithic C 18 column (150 mm × 0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C 18 column (150 mm × 0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorp…
In-tube solid-phase microextraction and liquid chromatography using a monolithic column for the selective determination of residual ethylenediamine i…
2009
The selective determination of the diamine ethylenediamine (EDA) in the presence of a higher amount of residual dimethylamine in cationic polymers has been developed. The strategy uses both a solution derivatization with a selective agent of primary amines such as o-phthaldialdehyde-N-acetyl-L-cysteine (OPA-NAC) and an in-tube solid-phase microextraction (IT-SPME) coupled to liquid chromatography (LC). A 70 cm long, 0.32 mm internal diameter, and 3 microm thick commercially available capillary column coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane was employed to replace the injection loop of a Rheodyne injection valve. A volume of 1 mL of derivatized sample was passed thro…
Sensitive determination of polycyclic aromatic hydrocarbons in water samples using monolithic capillary solid-phase extraction and on-line thermal de…
2011
A methacrylate-based monolithic capillary column has been evaluated for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. For this purpose, the monolyte was in situ synthesized in a 6cm×0.32mm id fused-silica capillary. The microextraction unit was fitted to a micro-HPLC pump to pass 10mL of sample. The isolated pollutants were eluted by means of 10μL of methanol, the organic phase being directly collected in a specific interface that can be fitted to the injection port of the gas chromatograph without modification. The interface allows the on-line thermal desorption of the PAHs, avoiding the dilution and providing enough sensitivity to reach …
Origin and correction of the deviations in retention times at increasing flow rate with Chromolith columns.
2010
Chromoliths can be used at flow rates beyond those feasible for conventional microparticulate packed columns. Ideally, the plots of the retention time versus the inverse of delivered flow rate should exhibit y-intercept of zero. However, significant positive deviations correlating with the solute polarity were observed for several compounds chromatographed with a Chromolith column, owing to the increased system pressure. Consequently, the dead time marker exhibits a smaller deviation, making the retention factors depend on the flow rate. Chromoliths are made of a silica-based monolith encapsulated within a PEEK tube, and should suffer larger stress with pressure than stainless steel columns…
Study of elution behaviour with gradient voltage in CEC using methacrylate monolithic columns.
2010
A theoretical study on the retention behaviour and chromatographic performance of neutral solutes using a lauryl methacrylate-based monolithic column under voltage gradient mode in CEC was carried out. Through a flexible mathematical function based on a modified Gaussian model, the peak shape of compounds was firstly fitted under constant and gradient voltage. Using the peak shape parameters and retention time, the estimation of global chromatographic performance, efficiency and peak capacity under several voltage conditions was performed. The influence of voltage gradient on the separation efficiency is discussed and simple equations are presented to calculate retention and peak widths und…
Development of Methods for the Determination of Ts, T3s and Sterols in Vegetable Oils
2012
In this work, a CEC method using methacrylate ester-based monolithic columns was developed to determine Ts and T3s present in edible oils. The potential of this method to evaluate olive oil adulteration with lower-cost oils of a different botanical origin was also investigated. For these purposes, the following vegetable oils were used: soybean, sunflower, grapeseed, EVOO (Coosur), hazelnut (Guinama), corn (Hacendado) and red palm (Blue Bay).
Monolithic silica columns of various format in automated sample clean-up/multidimensional liquid chromatography/mass spectrometry for peptidomics.
2007
The following particulate and monolithic silica columns were implemented in a fully automated and flexible multidimensional LC/MS system with integrated sample clean-up, to perform the analysis of endogeneous peptides from filtered urine and plasma samples: restricted access sulphonic acid strong cation-exchanger (RAM-SCX) for sample clean-up, RP 18 Chromolith guard columns as trap columns and 100 microm I.D. monolithic RP 18 fused silica capillary columns as last LC dimension. The results show sufficient overall system reproducibility and repeatability. Implementation of monolithic silica columns added an additional flexibility with respect to flow rate variation and adjustment due to the …